Controls Group http://www.controls-group.com/images/logo_controls.gif Hot mix asphalt automatic closed loop extractor PAVE ANALYZER Hot mix asphalt automatic closed loop extractor PAVE ANALYZER 75-PV50A05
close
Asphalt/bituminous mixture

Hot mix asphalt automatic closed loop extractor PAVE ANALYZER

For separation and extraction of bitumen, filler and aggregates from asphalt samples by use of solvents. By PAVELAB® SYSTEMS

  • Download:
ASTM D2172 | EN 12697-1
Main features
  • Ensures the most convenient testing conditions in a healthy environment (neither fumes nor noises); 
  • fully automatic test cycle improved by the combined effect of solvent and ultrasonic motion;
  • weighing and recording integrated system for the automatic calculation of the results;
  • automatic recovery of the solvent by continuous distillation process;
  • compatibility with the widest range of solvents as perchlorethylene, trichloroethylene and methilene chloride;
  • 7" touch screen swinging panel;
  • a distinguishing aesthetically pleasant design featured by ergonomic shrewdness to facilitate testing operations;
  • fast connection for rotary evaporator flask (available as option);
  • extraction time reduced to approx. 55 minutes (including drying).
General description
General description
The PAVELAB 50 Pave Analyzer represents the second generation of automatic closed loop bitumen and binder extractor developed by PAVELAB® SYSTEMS.  This new machine has been provided with key features that makes it a unique system currently available in the international market.
The Pavelab50 Pave Analyzer allows the complete analysis of an asphalt sample. It is used either to determinate the binder content or to recover, using a rotary evaporator, a representative bitumen sample used to perform other tests such as penetration, softening point, etc.
Furthermore aggregates, including filler, are also separated, not disturbed by high temperatures and available for sample grading.


The asphalt sample (max. 3.5 kg) is introduced in a screening drum lined with 0.063, 0.075 or 0.090 mm opening woven cloth and then placed inside a screening drum in the washing chamber. Bitumen and filler are separated from the sample by washing with solvent and ultrasonic motion. The mixture filler/bitumen/solvent is centrifuged and the filler is separated. The aggregates and filler are dried by force air circulation and the residue of solvent recovered by condensation.
The remaining solution bitumen/solvent  is then distilled and separated in two different tanks. Part of the solution bitumen/solvent can be drained before distillation and connected to a rotary evaporator  to recover a bitumen sample for other tests.
The clean distilled solvent is recycled for other extractions.
The machine stops immediately in case of door/cover openings, lack of water, electric motor malfunctions, etc. The door is locked when the test is running. Type of trouble is evidenced on the control panel display.
The analyzer shall be connected to a suitable water cooling unit to feed the three different cooling coils of the apparatus.
The laboratory can be completely safe from solvent vapours by filling the solvent in the machine with the solvent filling device (see Accessories).

The machine is composed by the following components:
  • 7” touch screen swinging panel displays the operating stage and recorded data. Machine software enable the test parameters set up;
  • Distiller cover top can be upgraded with a balance in order to weight the sample at the end of each stage. Weight data are recorded by the software and used for automatic result calculations (for 75-PV50A25, 75-PV50A26);
  • The condenser cleaning operations are facilitated by an hinged opening of the lid;
  • Level indicators are made of a high resistance material in order to be compatible with a extensive range of solvents.
  • Drum housing in the stainless steel washing chamber fitted with ultrasonic equipment, heating system, driving device for the rotation
  • Centrifuge and cup housing suitable for 120 mm dia. cup. Safety switch integrated;
  • Double chamber recovery/distillation unit: The distillation chamber comprehends base and upper heater providing solvent recovery up to approx. 30 l/h, and cooling coils above the chamber, incorporated in the cover. Both chambers are fitted with drain valves.
  • Condenser: stainless steel tank complete with cooling coil for condensation of solvent vapor during the drying operation
  • A fast connection for rotary evaporator flask, for bitumen solution collection, is available as accessory.
More +

Technical specifications

Maximum sample weight: 3.5 kg
Centrifuge rotation speed: 6000 r.p.m.
Scale: 10 kg, 0.1 g res.
Cup dimensions: 120 mm dia,. x 200 mm height (ext. dim.)
Max filler cap.: 300 g approx.
Extraction time: 55 min. approx (including drying time)
Solvent per extraction: 10 l approx. (recycled)
Power rating: 6 kW (excluding cooling system)
Overall dimensions: 1400x750x1500 mm (wxdxh)
Weight: 240 kg approx.

Ordering info

75-PV50A15
PAVE ANALYZER automatic closed system asphalt analyzer for separation and exraction of bitumen, filler and aggregates from asphalt samples by use of solvents.
380 V, 50 Hz, 3 ph

75-PV50A16
PAVE ANALYZER automatic closed system asphalt analyzer for separation and exraction of bitumen, filler and aggregates from asphalt samples by use of solvents.  
220 V, 60 Hz, 3 ph

75-PV50A25
PAVE ANALYZER automatic closed system asphalt analyzer with integrated 10 kg scale (0.1 g resolution) for separation and extraction of bitumen, filler and aggregates from asphalt samples by use of solvents. 
380 V, 50 Hz, 3 ph.

75-PV50A26
PAVE ANALYZER Automatic closed system asphalt analyzer with integrated 10 kg scale (0.1 g resolution) for separation and extraction of bitumen, filler and aggregates from asphalt samples by use of solvents. 
220 V, 60 Hz, 3 ph.

Accessories

Washing drums and closing lid
75-PV50/KIT kit of accessories complete with:
75-PV5X010 Washing drum 0.063 mm opening
75-PV5X040 Closing lid for washing drums
75-PV5X150 Centrifuge cup, 120 mm dia.
75-PV0005/2 Lining paper for centrifuge cup. Pack of 100.
75-PV5X010 Washing drum 0.063 mm opening
75-PV5X010/C Washing drum 0.063 mm opening with traceable certificate of wire mesh opening
75-PV5X020 Washing drum 0.075 mm opening
75-PV5X020/C Washing drum 0.075 mm opening with traceable certificate of wire mesh opening
75-PV5X030 Washing drum 0.090 mm opening
75-PV5X030/C Washing drum 0.090 mm opening with traceable certificate of wire mesh opening
75-PV5X040 Closing lid for washing drums

Solvent testing device
75-PV5X110
Testing device to verify the stability of recycled perchlorethylene from the pH value.
75-PV5X120
Solvent stabilizator. 1000 ml bottle. For restabilization of recycled perchlorethylene.

Water cooling system
75-PV5X135
Water cooling system providing water between 10°C and 15°C, with flow rate 5 l/min,  pressure 3 bar. 380 V, 50 Hz, 3 ph
75-PV5X136
Water cooling system providing water between 10°C and 15°C, with flow rate 5 l/min,  pressure 3 bar. 220 V, 60 Hz, 3 ph
75-PV5X180
Upgrade of the cooling system series 75-PV5X13X with fast connection pipes

Centrifuge cup
75-PV5X150
Centrifuge cup, 120mm diameter.
75-PV0005/2 
Lining paper for centrifuge cup. Pack of 100.
75-PV5X160
Device for the extraction of the centrifuge cup.

Solvent filling device
75-PV5X200

Solvent pumping device for safe Pave Analyzer solvent filling. This universal system allows to pump the solvent from any kind of tank to the Pave Analyzer tank in a safe way without dispersed solvent vapours in the laboratory. The system is composed by a 25 liter tank, a motorized vacuum pump, hoses and connection to asphalt analyzer. The operator needs only to connect hoses and activate the electrical pump in order to pump solvent from the solvent supplier tank to the Pave Analyzer. 230V/50Hz/1ph

Rotary evaporator flask connection
75-PV5X100

Fast connection for rotary evaporation flask for bitumen solution sampling (to be ordered at time of order).

Tap water connection
75-PV5X170

Upgrade with additional electrovalve at the cooling water inlet, that stops the water flow when the dirty solvent has been completely recovered, reducing the consumption of tap water. Suitable for tap water use only.

Calibration
75-PV5X190

Traceable calibration report  for the integrated weight scale of the Pave Analyzer series 75-PV50A2X

Documents